Bare Stranded Aluminium Conductor (Overhead)

BARE STRANDED ALUMINIUM CONDUCTOR 0.6/1KV

Specification: NIS/IEC 60228A                                                                                             Type: BSAC

Ref: BS 215 part 1, IEC 61089, NIS 231

Application: Overhead Power Transmission

 

 

 

 

 

 

 

Nominal Cross sectional area

 

 

 

 

 

mm2

Conductor Number x diameter of wire

 

 

 

mm

Nominal overall diameter

 

 

 

 

mm

Maximum

current

rating

 

 

 

A

Approx. Net weight

Kg/

standard

length

 

kg

Standard delivery length

 

 

 

 

m

Delivery from

 

 

 

 

 

 

 

in ground

in air

16RS

7 x 1.70

5.1

-

96

264

6,000

R10

25RS

7 x 2.12

6.4

-

126

272

4,000

R10

35RS

7 x 2.50

7.5

-

157

282

3,000

R10

50RS

7 x 3.10

9.3

-

205

435

3,000

R10

50RS

19 x 1.80

9.0

-

196

399

3,000

R10

70RS

19 x 2.12

10.6

-

235

555

3,000

R12

95RS

19 x 2.50

12.5

-

296

768

3,000

R12

100RS

19 x 2.67

13.4

-

316

876

3,000

R12

120RS

19 x 2.80

14.0

-

339

805

2,500

R12

150RS

19 x 3.25

16.3

-

400

868

2,000

R12

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RS = Round Stranded Conductor.

 

BARE ALUMINIUM CONDUCTOR STEEL RE-ENFORCED 0.6/1 KV

Application: Overhead Power Transmission

Specification: NIS/IEC 60228A                                                                                             Type: ACSR

Ref: BS 215part 11, IEC 61089, NIS 234.

 

 

 

 

 

 

 

 


Nominal Cross sectional area

 

 

 

 

mm2

Conductor Number x diameter of wire

 

 

 

 

mm

 

 

 

Code name

 

 

Nominal overall diameter

 

 

 

 

 

mm

 

Maximum

current rating

A

Approx. Net weight

Kg/

standard

length

 

kg

Standard

delivery

length

 

 

 

 

 

m

 

Delivery form

 

 

 

 

100

7 x 1.57 St

6 x 4.72 Al

Dog

14.15

-

327

985

2000

R12

150

7 x 2.59 St

30 x 2.59 Al

Wolf

 

18.1

-

423

2178

3000

R16

 

200

7 x 3.00 St

30 x 3.00 Al

Panther

21.0

-

531

1948

2000

R16

265

7 x 3.35 St

30 x 3.35 Al

Bear

23.5

-

579

2426

2000

R18

380

7 x 3.00 St

54 x 3.00 Al

Bison

27.0

-

733

2121

1500

R18

430

7 x 4.27 St

30 x 4.27 Al

Dear

29.9

-

792

1971

1000

R18

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.