PVC Insulated & Sheathed Armoured Cables

PVC INSULATED & SHEATHED ARMOURED CABLES OF DIFFERENT SIZES

Application: For indoor installations, in cable ducts/trays, and underground in industrial plants, sub-stations and power utility distribution schemes with additional protection where mechanical damage may be expected.

1. Copper Conductor

2. PVC – Insulation

3. PVC – Inner Sheath

4. Round or Flat Al Wire Armouring

5. PVC –Outer Sheath

 

PVC INSULATED AND SHEATHED SINGLE-CORE ARMOURED COPPER CABLES 0.6/1 KV

Specification: BS 6346

Type: NCXXR/FX – 1-Core

 

 

Nominal Cross sectional area

mm2

 

 

Conductor Number x diameter of wire

mm

 

 

 

 

Radial thickness of

 

 

 

 

 

 

 

Nominal overall diameter

 

 

 

 

 

 

 

Maximum current  rating

 

 

 

 

 

Approx. Net Weight Kg/standard             length

 

 

 

 

Standard delivery length

 

 

Delivery form

Insula tion

Inner sheath

Outer sheath

 

In Ground

In Air

mm

mm

mm

mm

A

A

kg

m

drum

50RS

19x1.78

1.4

0.8

1.5

19.1

195

167

1024

1000

R12

70RS

19x2.12

1.4

0.8

1.6

21.1

238

216

1034

1000

R14

95RS

19x2.50

1.6

0.8

1.6

23.4

286

264

1665

1000

R14

120RS

19x2.80

1.6

1.0

1.7

26.3

325

308

1701

1000

R14

150RS

37x2.25

1.8

1.0

1.7

28.3

365

356

2018

1000

R16

185RS

37x2.52

2.0

1.0

1.8

30.8

413

409

1232

500

R14

240RS

61x2.25

2.2

1.0

1.9

34.1

479

485

1610

500

R16

300RS

61x2.52

2.4

1.0

1.9

37.0

541

561

1834

500

R16

400RS

61x2.85

2.6

1.2

2.1

42.0

614

656

2459

500

R18

500RS

61x3.20

2.8

1.2

2.1

45.6

693

749

2471

500

R18

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

 RS = Round Stranded Conductor

 

PVC INSULATED AND SHEATHED TWO – CORE ARMOURED COPPER CABLES 0.6/1 KV

Specification: NIS 172, BS 6346

Type: NCXXR/FX – 2-Core

 

Nominal Cross sectional area

mm

 

Conductor Number x diameter   of wire

mm

 

 

Radial thickness of

 

 

 

Nominal overall diameter   

 

 

 

Maximum current  rating

 

 

Approx.    Net     Weight Kg/standard

length

 

Standard delivery

 length

Delivery form

Insula

tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

A

A

kg

m

drum

1.5RW

2x1.38

0.8

0.8

1.8

13.0

25

17

316

1000

R10

2.5RW

2x1.78

0.9

0.8

1.8

14.2

34

23

391

1000

R10

4.0RW

2x2.25

1.0

0.8

1.8

16.3

45

31

560

1000

R12

6.0RW

2x2.76

1.0

0.8

1.8

17.3

55

40

650

1000

R12

10RS

2x7/1.35

1.0

0.8

1.8

19.9

74

55

881

1000

R12

16RS

2x7/1.70

1.0

0.8

1.8

22.2

97

74

1155

1000

R14

25RS

2x7/2.14

1.2

1.0

2.0

25.2

126

98

1639

1000

R14

35RS

2x7/2.52

1.2

1.0

2.0

27.6

151

120

1843

1000

R16

50RS

2x19/1.78

1.4

1.0

1.9

30.8

211

180

1163

500

R14

70RS

2x19/2.12

1.4

1.0

1.9

35.2

261

232

1542

500

R16

95RS

2x19/2.52

1.6

1.2

2.1

40

309

282

2034

500

R18

120RS

2x37/2.03

1.6

1.2

2.2

41.6

351

328

2435

500

R18

150RS

2x37/2.25

1.8

1.2

2.3

48.2

397

379

2951

500

R20

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RW = Round Solid Wire (conductor)

  RS = Round Stranded Conductor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

PVC INSULATED AND SHEATHED THREE–CORE ARMOURED COPPER CABLES 0.6/1 KV

Specification: BS 6346, NIS/IEC 60502-1

Type: NCXXR/FX – 3-Core

 

 

Nominal Cross sectional area

 

mm2

 

 

Conductor Number x diameter of wire

 

mm

 

 

 

Radial thickness of

 

 

 

 

 

 

Nominal overall diameter

 

 

 

 

 

Maximum current  rating

 

Approx. Net weight Kg/standard length

 

   Standard delivery  length

 

Delivery form

Insula

tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

A

A

kg

m

drum

1.5RW

3x1.38

0.6

0.8

1.4

13.5

23

15

340

1000

R10

2.5RW

3x1.78

0.7

0.8

1.4

14.8

30

21

418

1000

R10

4.0RW

3x2.25

0.8

0.8

1.4

17.0

39

28

599

1000

R12

6.0RW

3x2.76

0.8

0.8

1.5

18.0

49

36

703

1000

R12

10RS

3x7/1.35

1.0

0.8

1.6

21.1

65

50

1004

1000

R12

16RS

3x7/1.70

1.0

0.8

1.6

24.1

84

66

1348

1000

R14

25RS

3x7/2.12

1.2

1.0

1.7

26.6

109

88

1677

1000

R14

35RS

3x7/2.52

1.2

1.0

1.8

29.2

130

109

2110

1000

R16

50RS

3x19/1.78

1.4

1.0

1.9

30.5

174

153

2249

1000

R16

70RS

3x19/2.12

1.4

1.2

2.0

35.0

216

196

1467

500

R14

95RS

3x19/2.50

1.6

1.2

2.0

39.3

256

238

1971

500

R16

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RW = Round Solid Conductor

  RS = Round Stranded Conductor.

PVC INSULATED AND SHEATHED FOUR–CORE ARMOURED COPPER MAINS CABLES 0.6/1 KV

Specification: BS 6346, NIS/IEC 60502-1

Type: NCXXR/FX – 4-Core

 

 

 

 

Nominal Cross sectional area

 

 

 

mm2

 

 

 

 

Conductor Number x diameter   of wire

 

 

 

mm

 

 

 

Radial thickness of

 

 

 

 

 

 

Nominal overall diameter

 

 

 

 

 

Maximum current    rating

 

 

Approx. Net weight  Kg/ standard length

 

  Standard delivery length

 

Delivery form

Insula

tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

A

A

kg

m

drum

1.5RW

4x1.38

0.6

0.8

1.4

13.5

26

18.5

399

1000

R10

2.5RW

4x1.78

0.7

0.8

1.4

14.5

34

25

549

1000

R12

4.0RW

4x2.25

0.8

0.8

1.4

17.8

44

34

710

1000

R12

6.0RW

4x2.76

0.8

0.8

1.5

19.2

56

43

837

1000

R12

10RS

4x7/1.35

1.0

0.8

1.6

22.8

74

60

1211

1000

R14

16RS

4x7/1.70

1.0

1.0

1.7

26.3

96

80

1430

1000

R14

25RS

4x7/2.12

1.2

1.0

1.8

303.7

123

101

1992

1000

R16

35RS

4x7/2.52

1.2

1.0

1.9

33.9

147

126

2243

1000

R16

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RW = Round Solid Wire (conductor)

  RS = Round Stranded Conductor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVC INSULATED AND SHEATHED TWO–CORE ARMOURED ALUMINIUM CABLES 0.6/1 KV

Specification: BS 6346, NIS/IEC 60502-1                                                   

Type: NAXXR/FX – 2-Core

 

 


 

Nominal Cross sectional area

 

 

 

mm2

 

 

 

   Conductor Number x diameter of wire

 

 

 

mm

 

 

 

Radial thickness of

 

 

 

 

Nominal overall diameter

 

 

 

Maximum current   rating

 

 

Approx. Net weight/

standard

length

Standard delivery length

Delivery form

Insula

Tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

Amp

Amp

kg

m

drum

16RS

2x7/1.70

1.0

0.8

1.6

20.7

89

73

846

1000

R14

25RS

2x7/2.12

1.2

1.0

1.7

25.0

114

89

915

1000

R14

35RS

2x7/2.50

1.2

1.0

1.8

27.2

137

111

1094

1000

R16

50RS

2x19/1.80

1.4

1.0

1.9

30.5

161

135

668

500

R14

70RS

2x19/2.12

1.4

1.2

1.9

32.7

200

173

848

500

R16

95RS

4x19/2.50

1.6

1.2

2.1

37.4

237

210

1069

500

R18

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

  RS = Round Stranded Conductor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVC INSULATED AND SHEATHED THREE–CORE ARMOURED ALUMINIUM MAINS CABLES 0.6/1 KV

Specification: BS 6346, NIS/IEC 60502-1

Type: NAXXR/FX – 3-Core

 

 

 

Nominal Cross sectional area

 

 

 

mm2

 

 

 

Conductor Number x diameter of wire

 

 

 

mm

 

 

 

Radial thickness of

 

 

 

 

Nominal overall diameter

 

 

 

Maximum current  rating

 

 

Approx. Net weight/

standard

length

 

Standard

delivery

length

Delivery form

Insula

tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

Amp

Amp

kg

m

drum

16RS

3x7/1.70

1.0

0.8

1.6

21.8

74

61

913

1000

R14

25RS

3x7/2.12

1.2

1.0

1.7

26.4

94

78

1003

1000

R14

35RS

3x7/2.50

1.2

1.0

1.8

28.7

114

96

1226

1000

R14

50RS

3x19/1.80

1.4

1.0

1.9

31.9

134

117

1317

1000

R16

70RS

3x19/2.12

1.4

1.2

2.0

36.0

167

150

803

500

R14

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RS = Round Stranded Conductor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVC INSULATED AND SHEATHED FOUR–CORE ARMOURED ALUMINIUM MAINS CABLES 0.6/1 KV

Specification: BS 6346, NIS/IEC 60502-1

Type: NAXXR/FX – 4-Core

 

 

 

 

Nominal Cross sectional area

 

 

 

mm2

 

 

 

 

Conductor Number x diameter of wire

 

 

 

mm

 

 

 

 

Radial thickness of

 

 

 

 

 

Nominal overall diameter

 

 

 

 

Maximum current   rating

 

 

 

Approx. Net weight/

standard

length

 

Standard delivery length

Delivery form

Insula

tion

Inner sheath

Outer sheath

 

In

ground

In air

mm

mm

mm

mm

Amp

Amp

kg

m

drum

16RS

4x7/1.70

1.0

1.0

1.7

24.8

74

61

601

1000

R14

25RS

4x7/2.12

1.2

1.0

1.8

28.7

94

78

888

1000

R16

35RS

4x7/2.50

1.2

1.0

1.9

31.3

114

96

1285

1000

R16

Note:

  1. Maximum permissible conductor temperature under service condition is taken at 700C.
  2. Maximum current rating in ground is considered at ground temperature of 350C.
  3. Maximum current rating in air is considered at a temperature of 400C.

RS = Round Stranded Conductor